100 Ltr Solvent Recovery machine

No. TEN254193
  • What is Product No. and what is its purpose?

Click here for details

100 Ltr Solvent Recovery machine

Page Views:123
  • 2010-03-22
  • 2010-04-06
  • Gujarat India
  • Bulk
  • FOB
  • Negotiable

INNOVATIVE FLEXOTECH PVT LTD India INNOVATIVE FLEXOTECH PVT LTD

  •  Mr. Thakar
  •  91-2715-235390 / 235391
  •  91-982-4096180
  •  91-9824096180
  •  435, Patel Avenue, Nr. Gurudwara, S. G. Road, ,Gujarat
  •  http://www.flexo.co.in

Brief Description

Product Attributes

Related attributes of 100 Ltr Solvent Recovery machine:
  • Place of Origin:Gujarat India

Detailed Description

Detailed introduction to 100 Ltr Solvent Recovery machine:

SOLVENT RECOVERY UNIT 
@flexo 60L-RHB
@flexo 80L-RHB

@flexo 100L-RHB
SPECIAL FEATURES
Solvent recovery unit
For photopolymer flexo plates
A. General description:
@80L-RH is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information:
Recovery volume
60 / 80 liters
Power consume
220V 4. 65kw
Diathermic oil
23 KG
Machine dimension
1100x 780x1200 mm
Main body
Recovery rate
85%
C. Operating steps:
After opening the crate, plug in 220 V power, and connect the ground (earth) .
Open
Open the lid and fill the tank up to the level with solvent to be recovered (80 L)
Close the lid and tighten it.
Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1) .
Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C.
Vacuum tank pressure (3) high at 0. 03 Mpa / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C.
Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12) .
If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13) .
D. Important:
Install the unit in a wide and ventilated place.
Disconnect electric power before doing any action.
No taking off the control panel
Change the diathermic oil every 1000 working hours.
No filling the solvent container up over the level (80 liters)
Remove the waste after every recovery process

 

Can you supply these products? Post Your Products Now!

Related Products

Let supplier know exactly what you're looking for. Post Your Buying Leads Now!

Hot Products: cloth, car, diagnostic, portable office containers, food, pvc cosmetic bag, mobile phone, print, led, jeans, wireless, glass, stone, crusher, mp3, doll, computer, lcd, side, main Show All radio digital watch, software sites, plastic electric pipe fitting, decals stickers, enamel pendant, natural ascorbic acid, led butterfly, door lock switch, loofah bath sponge, coil steel, diner plate, sexy underclothes, gd 12, wired routers, naughty palace, cosmetic box design, skylight glass roof, Land Development Consulting, Messen, hybrid pos atm dvr Hide